LOG-FPRS380
Drive with a rated supply of 380 V at 50 Hz.
LOG-FPRS380 provides torque and speed data for assessing a fire roller shutter drive. The data sheet gives the supply and running time for review before final selection.
Request information
Tell us about your project and we will advise you on the most suitable solution.
- Rated torqueOutput torque informs the mechanical assessment.
- Linear speedSpeed in metres per minute can be compared with shutter travel.
- Electrical dataVoltage, frequency and current inform the panel review.
- Thermal protectionThe data sheet gives the protection threshold.
LOG-FPRS380
The data sheet gives 412 Nm rated torque, 4.8 m/min rated speed and 13 min continuous running time. The fabricator can compare these with the travel and operating sequence.
| Rated voltage and frequency | 380 V at 50 Hz |
|---|---|
| Rated output torque | 412 N·m |
| Rated output speed | 4.8 m/min |
| Motor power | 370 W |
| Rated current | 1.5 A |
| Stated continuous running time | 13 min |
| Manual operation without mains power | Yes |
| Overheat protection | 120 °C |
| Limit switch protection | Yes |
Source: product data sheet.
Drive for fire roller shutters
The installer uses the panel schematic to review supply and controls. Final selection uses the data for the shutter and this variant.
- Fire roller shutters. Review the drive against shutter data.
- Control panel integration. Review supply and the intended sequence.
- Variant selection. Assess the drive using output torque and speed.
LOG-FPRS380
What rated speed does the data sheet give?
It gives 4.8 m/min.
What continuous running time is stated?
The data sheet states 13 min.
What thermal protection is listed?
The data sheet lists 120 °C.
Which details are outstanding for final selection?
Maximum load, phase count, lifting height and brake configuration are to be confirmed.
What do you review at the control panel?
The available supply and intended operating sequence.
What information do you need to assess my project?
Send the shutter type, weight, height, travel, supply and panel schematic.
Fire door automation
Single-phase drive for fire shutters
230 V AC drive with a 24 V brake.
View productFire closure project assessment
Early assessment of the closure, available space and operating sequence.
View productIntegration assessment for fire closures
Review of the closure, control panel and proposed signals.
View productNeed to automate something complex?
Tell us what needs to move, how much it weighs and where it goes. We will study it with you.