LOG-FPRS230
230 V AC drive with a 24 V brake.
LOG-FPRS230 is the single-phase 230 V drive with a 24 V brake for fire roller shutters, in 600 kg and 800 kg versions. The data sheet lists motor supply and brake voltage separately, making it easier to check the control panel interface.
Request information
Tell us about your project and we will advise you on the most suitable solution.
- Single-phase supplyThe data sheet identifies the motor supply.
- Brake voltageThe 24 V brake is listed separately.
- Sizing dataTorque, load and lifting height guide selection.
- Documented dutyThe S2 rating and stated running time inform the assessment.
LOG-FPRS230
The shutter fabricator checks load and lifting height against the torque and load data. The rating is S2 duty with an operating time of 7 min.
| Supply | 230 V AC at 50 Hz |
|---|---|
| Phases | 1 |
| Brake | 24 V |
| Maximum door load (600 kg version) | 600 kg |
| Input power (600 kg version) | 836 W |
| Rated current (600 kg version) | 3.9 A |
| Output shaft torque (600 kg version) | 412 N·m |
| Output speed (600 kg version) | 4.8 r/min |
| Maximum door load (800 kg version) | 800 kg |
| Input power (800 kg version) | 920 W |
| Rated current (800 kg version) | 4.7 A |
| Output shaft torque (800 kg version) | 647 N·m |
| Output speed (800 kg version) | 4.0 r/min |
| Lifting height | 7 m |
| Operating time | 7 min |
| Duty | S2 |
| Insulation class | B |
| Ingress protection rating | IP40 |
| Operating temperature | −15 to +45 °C |
Source: product data sheet.
Single-phase drive for fire shutters
The installer uses the panel schematic to check the supply, brake and proposed operating sequence.
- Fire roller shutters. Select the drive against shutter weight and height.
- Panels with brake control. Review supply and the brake interface.
- Shutter integration. Coordinate the drive with the intended sequence.
LOG-FPRS230
What maximum load does it take?
There are two 230 V versions: one for doors up to 600 kg and one up to 800 kg, each with its own torque and power.
What voltage does the brake require?
The data sheet specifies a 24 V brake.
What lifting height is listed?
The stated lifting height is 7 m.
What duty rating is listed?
S2 duty with an operating time of 7 min.
What do you check at the control panel?
The motor supply, brake interface and shutter sequence.
What information do you need to assess my project?
Send the shutter type, weight, height, travel, supply and panel schematic.
Fire door automation
Drive for fire roller shutters
Drive with a rated supply of 380 V at 50 Hz.
View productFire closure project assessment
Early assessment of the closure, available space and operating sequence.
View productIntegration assessment for fire closures
Review of the closure, control panel and proposed signals.
View productNeed to automate something complex?
Tell us what needs to move, how much it weighs and where it goes. We will study it with you.